MIDSUMMER

We offer attractive prices to the trade. Please login or register for an account.

Login Create an account
01223 851535
trade@midsummerenergy.co.uk
Ex Vat Inc Vat
Ex Vat Inc Vat

SolShare 35 Basic Bundle

SolShare

Log in or register for trade discounts!

Quantity:
BUY!

tell me more

Allume’s SolShare is the world’s first power division control system (PDCS). Providing functionality to supply the AC energy outputted from a solar inverter to multiple grid-connected units behind-the-meter. The SolShare opens the solar market to apartments and businesses that share a roof.

The SolShare unit is placed between the inverter and the main switchboard. Receiving one three-phase AC input from the inverter and outputting up to 15 single-phase or 5 three-phase AC outputs (or a combination of both). Outputs are wired on the load side of each unit’s meter, at the building’s common main switchboard.

Technical information can be found here

Major markets:

Benefits to you, the installer:

  • Simple installation
  • Ongoing revenue opportunity for you via SolCentre subscription
  • Reduced fire regs complexity
  • Communal hardware
  • No issue with panel placement effecting flat yield

Benefits to the customer:

  • Increasing SAP points and EPC ratings
  • Ongoing revenue generation from SEG (not possible with individual systems)
  • Data monitoring and reporting (generating ongoing revenue for you, the installer)
  • Lower electricity bills and talking fuel poverty for residents
  • No hardware in the flats, no DC cabling running to each flat, reduced fire regulation.
  • Fully remote fault and underperformance alerts.

Installation Requirements:

  • It is recommended that there are at least 2 outputs connected on each phase. Example minimum connections:
    - 6 x single-phase
    - 2 x three-phase
    - 1 x three-phase plus 3 x single-phase
  • Ganged/co-located smart meters and main switches
  • Cable access between SolShare unit and central main switchboard
  • Installation must be carried out by a licensed electrician who has gained SolShare Installation certification
  • SolShare must be kept free of dust and water ingress during installation

To learn more about the major advantages of a SolShare solar system over traditional methods and to be come certified, contact Midsummer or Allume: commercial@midsummerenergy.co.uk or uk.info@allumeenergy.com.

Electrical Specifications
Max nominal current
35 A
Voltage range
216 – 260 VAC
Voltage drop
Frequency
Overcurrent rating
Max power input:
Input Power Factor 
2.8 V
50 – 60 Hz
30 kA
22 kW
1
General Specifications
Dimensions (HxWxD)
920x485 x270mm 
Weight
38kg
Max connections per unit
15 single-phase or 5 three-phase
Protection Rating
IP56
Operating temperature
-20 to +50°C